TCX® (I) 331 150/250 (300) V

Products

TCX® ( I ) 331 2P0.75

Product ref. 10280539

  • Packaging: Drum (100000m)
  • Number of pairs: 2
  • 도체 단면적: 0.75 mm²
  • Minimum outer diameter: 12.6 mm
  • Maximum outer diameter: 14.6 mm
  • 무게(근사치): 180 kg/km

 

TCX® ( I ) 331 14P0.75

Product ref. 10199548

  • Packaging: Drum (100000m)
  • Number of pairs: 14
  • 도체 단면적: 0.75 mm²
  • Minimum outer diameter: 23.8 mm
  • Maximum outer diameter: 27.4 mm
  • 무게(근사치): 798 kg/km

 

TCX® ( I ) 331 2P1.5

Product ref. 10280538

  • Packaging: Drum (100000m)
  • Number of pairs: 2
  • 도체 단면적: 1.5 mm²
  • Minimum outer diameter: 15.2 mm
  • Maximum outer diameter: 17.4 mm
  • 무게(근사치): 292 kg/km

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60331-1 or 2; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TCX® (I) 331  150/250 V fire resistant armoured individually screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 180 minutes. These telecommunication and instrumentation cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) 331  cables are used for detection and warning systems where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

1. Conductor
    Stranded bare copper class 2

2. Insulation
    Mica tape + XLPE (cross-linked polyethylene)

3. Individual screen
    Alu/polyester tape with a tinned copper drain wire

4. Inner covering
    Lapped polyester tape

5. Armouring
    Bare copper braid

6. Outer sheath
    Polyolefin SHF1
    Colour: orange

 

Example of marking: 
LYNXEO 279  TCX (I) 331 150/250 V  "n" x 2 or 3 x "s" mm²  90°C IEC 60092-376 IEC 60332-3-22 Cat. A  IEC 60331-1/2 "ww/yy" * CE *  TCIF + metric marking

Core Identification
Pair: white / blue with printed with pair number
Triad: white / blue / red with printed with triad number

OTHER CHARACTERISTICS

Test Voltage
AC between cores of the same unit.......................................................................... 1.5 kV AC


Minimum bending radius for fixed installations
• TCX® (I) 331............................................................................................. 6 x outer diameter

Characteristics

Characteristics

구조적 특성

구조적 특성

Halogen free
IEC 60754-1

치수

치수

Number of triples
-

전기적 특성

전기적 특성

정격전압 Uo/U (Um)
150 / 250 (300) V

사용 특성

사용 특성

Fire resistant
IEC 60331­-1 or -2
Fire retardant
EN IEC 60332-3-22 (cat A)
연기밀도
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
操作温度范围
-30 ... 80 °C
Max. conductor temperature in service
90 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close